Showing results: 241 - 255 of 1350 items found.
-
Fluke 1621 GEO -
Iconic Engineering Limited
The Fluke 1621 is an user-manageable-to-use earth showground tester. For arena resistance psychoanalysis, 1621 is the first pedigree of excuse in detecting honorable sports ground intimates. The unit features basic arena testing methods including 3-pole Fall-of-Potential as accurately as 2-pole sports arena resistance tests.
-
40-121-012 -
Pickering Interfaces Ltd.
The 40-121-012 provides 8x 2:1 multiplexers in a single slot PXI module and designed to provide an isolation resistance in excess of 1013Ω. It has been designed to ensure high isolation resistance through the use of switched guards, making it ideal for low level measurements and semiconductor test.
-
19572 -
Chroma Systems Solutions, Inc.
Wide resistance measurement range : 0.1 ~ 510 mΩHigh performance AC current output : 45 ACompact size ground bond testerProvide reliable and stable test resultsBuilt-in resistance compensation functionStandard RS-232 interfaceOptional GPIB InterfaceCompatible with the model 19070 series Hipot Tester2-Year factory warranty
-
40-121-011 -
Pickering Interfaces Ltd.
The 40-121-011 provides 16x 2:1 multiplexers in a single slot PXI module and designed to provide an isolation resistance in excess of 1013Ω. It has been designed to ensure high isolation resistance through the use of switched guards, making it ideal for low level measurements and semiconductor test.
-
CMP-401 -
Sonel S.A.
DC current measurement and AC current.AC/DC voltage measurement up to 600V.Resistance measurement and continuity test: * continuity test with acoustic signalling (beeper) for resistance below 50.Temperature measurement (Fahrenheit and Celsius units).
-
TRMS 6000 -
AstroAI Corp.
WIDE RANGE of tests for Voltage, Current, Resistance, Continuity, Capacitance, Frequency; Tests Diodes Transistors, TemperaturePROFESSIONAL LEVEL features include Auto-Ranging capability, and True RMS for measuring both AC Current and Voltage
-
Curtiss Wright IMR Test Labs
Hardness testing is a basic test used to verify raw materials or as a quick check for materials that fail or aren't performing as expected. Hardness tests quantify the resistance of a material to plastic deformation and is available as microindentation or macroindentation.
-
779771-01 -
NI
The PCIe‑4065 makes AC/DC voltage, AC/DC current, and 2‑ or 4‑wire resistance measurements, as well as diode tests. It is ideally suited for OEMs, educational laboratories, or other cost-conscious test and measurement applications.
-
779770-01 -
NI
The PCI‑4065 makes AC/DC voltage, AC/DC current, and 2‑ or 4‑wire resistance measurements, as well as diode tests. It is ideally suited for OEMs, educational laboratories, or other cost-conscious test and measurement applications.
-
780152-01 -
NI
The USB‑4065 makes AC/DC voltage, AC/DC current, and 2‑ or 4‑wire resistance measurements, as well as diode tests. It is ideally suited for OEMs, educational laboratories, or other cost-conscious test and measurement applications.
-
STCS -
Altanova Group
The external module STCS allows performing automatically the following PT tests: ratio per tap; winding resistance; OLTC dynamic test. The connection to the transformer under test, to STS and to the measurement taps is performed just once; then, all transformer tests are performed without interruptions.
-
MI-20KVe -
MEGABRAS srl
The MI-20KVe High-Voltage Megohmmeter is a truly portable device that allows the measurement of insulation resistances using test voltages up to 20 kV. It employs a state-of-the-art technology for the safe measurements of insulation resistances up to 4.000.000 MΩ with four test voltages: 5 kV - 10 kV - 15 kV and 20 kV. Readings are performed through an easy-to-read analogue indicator, having a broad scale.
-
UL 746A -
National Technical Systems
The High Voltage Tracking Resistance (HVTR) test method is used to assess the susceptibility to tracking of insulating materials that are exposed to high voltages outdoors. Insulators installed in the open are often at the mercy of humidity. Their electrical insulation properties can deteriorate to such an extent as a result that tracking paths are formed on the insulator surface. This test determines the tracking resistance that defines the dielectric strength of the insulating material surface and the maximum allowable leakage current (tracking).
-
DR-5 -
Daerim Electronics Co.
The DR-5 is designed for repairing line faults and installing new telephone lines, especially for the MDF in unmanned offices which do not have their own test board.1. Insulation resistance measuring2. Loop resistance measuring3. DC voltage measuring4. Terminal, Line capacity measuring5. Subscriber calling6. Dialing(Tone, Pulse type)7. Transmitting, receiving, waiting, and three way calling8. Test tone transmitting9. Four type melody soundInsulation resistance measuring range: DC180V / 50Mega OhmLoop resistance measuring range : 0 ~ 500Kilo OhmDC voltage measuring range : 0 ~ 150VRing signal Range : 20Hz / 75VPower : DC12V, AC 85~260 Free voltageDimension : 330 * 220 * 140(m/m)Weight : 3.5kg
-
KU-1199 -
Kaise Corporation
Auto-SCAN Measurement. No need for selectingDC/AC Voltages and Resistance ranges.Only 11mm thick and 72g in Weight.Easy-to-read largeLCD.Equipped with carrying case.Gold-plated Test Lead Pins.